How to play Flux Clock
- Choose a test and read the turns, the flux or the field and area, and the time on the card.
- Find the change in flux through each turn, ΔΦ (use Φ = B·A with A in m²), and use ε = N·ΔΦ ÷ Δt with Δt in s.
- Type the size of the emf and press Start. The flux graph ramps and the emf graph shows the meter's reading.
- Compare the flat part of the emf graph with your orange dashed prediction.
Faraday's law: a voltage from changing flux
Magnetic flux Φ = B·A counts how much field passes through a loop. Faraday found that a coil feels a voltage only while that flux changes, and that the voltage is the rate of change: each turn gives ΔΦ ÷ Δt, and N turns in series give ε = N·ΔΦ ÷ Δt. So a flux graph that climbs in a straight line gives a flat emf, a steeper climb gives a bigger emf, and a flat flux graph, however high, gives none: a strong magnet at rest beside a coil induces nothing. It does not matter how the flux changes: the field may grow, the coil may move out of the field, or the coil may turn. The induced current always flows the way that opposes the change (Lenz's law, the minus sign in ε = −N·ΔΦ ÷ Δt), which is why the meter swings one way as the flux grows and the other way as it falls.
A focused learning model
Faraday's law, ε = N·ΔΦ ÷ Δt, with Φ = B·A and the field along the coil's axis (out of the screen). The flux per turn changes in a straight ramp, so the emf is constant while it changes and zero before and after; the coil has no self-inductance, and the meter takes no current. In the yank test the coil moves sideways at a steady speed off a pole larger than the coil, so its flux falls linearly. The meter is wired so a rising flux reads positive; only the size of the emf is asked. The field marks are as dense as the field (full at 0.5 T; in tests 1 and 2, full near 3.75 mWb). The runs last 0.1 to 0.8 s and are slowed to 4 s. Answers within 2% are right; the zero within 0.005 V.