How to play Transformer
- Choose a test and read the supply, the turns, and the current or efficiency on the card.
- Use V_s ÷ V_p = N_s ÷ N_p for voltages and turns, and V_p·I_p = V_s·I_s for currents (times the efficiency if it is given).
- Type your prediction. The battery shows that DC does nothing; press Start to switch to AC.
- Read the meters, the lamp, the two waves, and the power bars, and compare them with your orange prediction.
Transformers: Faraday's law in a ring of iron
A transformer is two coils wound on one iron core. An alternating current in the primary coil makes an alternating magnetic flux, and the iron carries almost all of it round to the secondary coil. Faraday's law says each turn feels an induced emf equal to the rate of change of the flux through it, and the same flux passes through every turn of both coils, so the voltages are in the ratio of the turns: V_s ÷ V_p = N_s ÷ N_p. Fewer turns on the secondary step the voltage down, more turns step it up. Energy is conserved, so a good transformer, about 95–99% efficient, gives out nearly the power it takes in: V_p·I_p ≈ V_s·I_s, and stepping the voltage up steps the current down by the same factor. That is why power lines run at high voltage (see Power Line). A transformer needs a changing flux: on a battery the flux is steady, and the secondary gets nothing. The core is made of thin insulated sheets so that currents induced in the iron itself waste little energy.
A focused learning model
The transformer is ideal (no losses, all the flux through both coils) unless an efficiency is given; then the power out is η·V_p·I_p and the rest heats the core and coils. Voltages and currents are rms values of a 50 Hz supply, which is drawn slowed down to one cycle per second; the run turns the supply up steadily over 2 s and holds it for 1 s, and the flux lags the voltage by a quarter cycle. The secondary feeds a lamp of fixed resistance (6 Ω, a 12 V, 24 W lamp, in the first three tests; in the last two, the load that draws the given current), and a lamp given more than 1.5 times its rated voltage burns out. Before each run the primary is on a 12 V battery, a demonstration, not a test: the flux is steady and nothing is induced. Coil loops are drawn in proportion to the turns, at most 14. Mains and transformer values are teaching examples, not safety limits. Answers within 2% are right.