Transformer: The Turns Ratio Sets the Voltage, and Power In Equals Power Out

An educational simulation game. Two coils on one iron ring: AC in the primary makes a changing flux, and the secondary gets an induced emf in the ratio of the turns. A lamp lights with the power; on a battery it stays dark. Predict voltages, turns, currents, and the power out.

Faraday's lawTransformers

TRANSFORMER

Step down

Ready
Enable JavaScript to switch the transformer on. The instructions and worked example remain readable.
Supply current IInduced current (tagged)Magnetic flux Φ in the coreYour prediction
The transformerV_s ÷ V_p = N_s ÷ N_p

Time

0.00 s

t

Secondary voltage

— V

V_s = V_p·N_s ÷ N_p

Primary current

— A

I_p

Secondary current

— A

I_s

Power out

— W

P_s = V_s·I_s

Predict before you start

Type your prediction to set things up. Start stays off until there is an answer.

Predict what comes out of the secondary.

Mission score—

Every answer must be within 2%: each earns 100 points. Getting it right on the first run adds 50. A run counts as soon as it starts.

✓ Right answer① First try

How to play Transformer

  1. Choose a test and read the supply, the turns, and the current or efficiency on the card.
  2. Use V_s ÷ V_p = N_s ÷ N_p for voltages and turns, and V_p·I_p = V_s·I_s for currents (times the efficiency if it is given).
  3. Type your prediction. The battery shows that DC does nothing; press Start to switch to AC.
  4. Read the meters, the lamp, the two waves, and the power bars, and compare them with your orange prediction.

Transformers: Faraday's law in a ring of iron

A transformer is two coils wound on one iron core. An alternating current in the primary coil makes an alternating magnetic flux, and the iron carries almost all of it round to the secondary coil. Faraday's law says each turn feels an induced emf equal to the rate of change of the flux through it, and the same flux passes through every turn of both coils, so the voltages are in the ratio of the turns: V_s ÷ V_p = N_s ÷ N_p. Fewer turns on the secondary step the voltage down, more turns step it up. Energy is conserved, so a good transformer, about 95–99% efficient, gives out nearly the power it takes in: V_p·I_p ≈ V_s·I_s, and stepping the voltage up steps the current down by the same factor. That is why power lines run at high voltage (see Power Line). A transformer needs a changing flux: on a battery the flux is steady, and the secondary gets nothing. The core is made of thin insulated sheets so that currents induced in the iron itself waste little energy.

A focused learning model

The transformer is ideal (no losses, all the flux through both coils) unless an efficiency is given; then the power out is η·V_p·I_p and the rest heats the core and coils. Voltages and currents are rms values of a 50 Hz supply, which is drawn slowed down to one cycle per second; the run turns the supply up steadily over 2 s and holds it for 1 s, and the flux lags the voltage by a quarter cycle. The secondary feeds a lamp of fixed resistance (6 Ω, a 12 V, 24 W lamp, in the first three tests; in the last two, the load that draws the given current), and a lamp given more than 1.5 times its rated voltage burns out. Before each run the primary is on a 12 V battery, a demonstration, not a test: the flux is steady and nothing is induced. Coil loops are drawn in proportion to the turns, at most 14. Mains and transformer values are teaching examples, not safety limits. Answers within 2% are right.

Changing language keeps your test, prediction, attempts, and run.