Heat Pump: Work Can Pump Heat Uphill, Several Joules per Joule, COP = Q_c ÷ W

An educational simulation game. A compressor hums, and heat flows the wrong way: out of a cold fridge, the cold outdoors, or a freezer, and into a warm room or house. A Sankey bar shows the heat moved, the work, and the heat delivered. Predict COPs, heat flows, the Carnot limit, and how long ice takes to form.

Heat enginesFridges and heat pumps

HEAT PUMP

A fridge's COP

Ready
Enable JavaScript to run the pump. The instructions and worked example remain readable.
Heat delivered Q_hHeat taken Q_cThe Carnot limitYour prediction
The heat pumpCOP = Q_c ÷ W, Q_h = Q_c + W

Time

0.00 s

t

COP

—

COP

Heat taken

—

Q_c

Heat delivered

—

Q_h

Predict before you start

Type your prediction to set things up. Start stays off until there is an answer.

Predict how much heat the work moves.

Mission score—

Every answer must be within 2%: each earns 100 points. Getting it right on the first run adds 50. A run counts as soon as it starts.

✓ Right answer① First try

How to play Heat Pump

  1. Choose a test and read the heat, the work, the COP, or the temperatures on the card.
  2. Use Q_h = Q_c + W, COP = Q_c ÷ W for a fridge (Q_h ÷ W for heating), and COP_max = T_c ÷ (T_h − T_c) in kelvin.
  3. Type your prediction and press Start. The compressor runs and the Sankey bar shows the flows.
  4. Compare the bars, the COP scale, or the ice with your orange prediction.

Fridges and heat pumps: engines run backwards

Heat never flows from cold to hot by itself, but work can force it to. A fridge pumps a refrigerant round a loop: it evaporates in the cold coils inside, taking heat Q_c from the food, is squeezed by the compressor, which adds the work W, and condenses in the warm coils at the back, giving out Q_h = Q_c + W to the kitchen. Because the work only has to lift the heat, not supply it, a fridge moves several joules of heat for each joule of electricity: its coefficient of performance COP = Q_c ÷ W is typically 2 to 4. A heat pump is the same machine facing the other way: it takes heat from the cold outdoors and delivers Q_h to a house, so its heating COP, Q_h ÷ W, is one more than its cooling COP, which is why it beats an electric heater three or four times over. The second law caps the COP at T_c ÷ (T_h − T_c) in kelvin: the smaller the temperature lift, the more heat each joule can move, so a heat pump struggles in deep cold and a fridge in a hot kitchen.

A focused learning model

Energy is conserved, Q_h = Q_c + W; flows are per cycle in J or rates in W and kW. A fridge's COP is Q_c ÷ W, a heat pump's heating COP Q_h ÷ W. The Carnot limit uses kelvin temperatures; in the best test the fridge is drawn running at the COP you typed, and a wrong answer that would beat the limit is drawn as an impossible machine. The freezer removes Q_c = COP × 100 W from water already at 0 °C, with L_f = 334 kJ/kg, and its real time is sped up to about 4 s; the other runs last 3 s. Answers within 2% are right.

Changing language keeps your test, prediction, attempts, and run.